Alpha Essentials Page 130 Tray Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 130 Tray Cable 300 V Overall and Individually Foil Shielded Pairs, Composite PVC/Nylon, PVC UL PLTC, ITC UL CL3 CSA CMG FT4 Operating Temperature -20C to +105C Conductor Color Coding Chart BW Materials Stranded bare copper conductors PVC/nylon insulation Aluminum/polyester foil shield, 25% overlap min. Foil facing inward Stranded tinned copper drain wire one even AWG size smaller than conductors Black PVC jacket Features UL Sunlight Resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length (Minimums may apply) 20 AWG (0.52 mm 2 )* Stranding: 7/0.0121 (7 x 0.31 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs Nominal Diameter Jacket Thickness Inch mm Inch mm M9740020 2 0.345 8.76 0.045 1.14 M9740040 4 0.423 10.74 0.053 1.35 M9740060 6 0.487 12.37 0.053 1.35 M9740080 8 0.539 13.69 0.053 1.35 M9740120 12 0.643 16.33 0.063 1.60 M9740160 16 0.724 18.39 0.063 1.60 5620B2020** 20 0.752 19.10 0.065 1.65 M9740240 24 0.882 22.40 0.073 1.85 M9740360 36 1.011 25.68 0.073 1.85 M9740500 50 1.169 29.69 0.073 1.85 *Communications wire is 22 AWG (0.35 mm 2 ), 7/30 (7 x 0.25 mm) stranding, bare copper with 0.016 (0.41 mm) thick insulation. **0.013 (0.33 mm) insulation thickness. 18 AWG (0.82 mm 2 ) Stranding: 7/0.0152 (7 x 0.39 mm) Insulation thickness: 0.016 (0.41 mm) PVC Part No. Pairs Nominal Diameter Jacket Thickness Inch mm Inch mm M9748020 2 0.397 10.08 0.053 1.35 M9748040 4 0.459 11.66 0.053 1.35 M9748060 6 0.541 13.74 0.053 1.35 M9748080 8 0.621 15.77 0.063 1.60 M9748120 12 0.723 18.36 0.063 1.60 M9748160 16 0.785 19.94 0.063 1.60 5620B1820 20 0.910 23.11 0.075 1.91 M9748240 24 0.980 24.89 0.073 1.85 M9748360 36 1.124 28.55 0.073 1.85 M9748500 50 1.329 33.76 0.083 2.11 *Communications wire is 22 AWG (0.35 mm 2 ), 7/30 (7 x 0.25 mm) stranding, bare copper with 0.016 (0.41 mm) thick insulation. 16 AWG (1.31 mm 2 ) Stranding: 7/0.0192 (7 x 0.49 mm) Insulation thickness: 0.016 (0.41 mm) PVC Part No. Pairs Nominal Diameter Jacket Thickness Inch mm Inch mm M9746020 2 0.439 11.15 0.053 1.35 M9746040 4 0.508 12.90 0.053 1.35 M9746060 6 0.624 15.85 0.063 1.60 M9746080 8 0.684 17.37 0.063 1.60 M9746120 12 0.810 20.57 0.063 1.60 M9746160 16 0.921 23.39 0.073 1.85 M9746240 24 1.123 28.52 0.073 1.85 M9746360 36 1.316 33.43 0.083 2.11 M9746500 50 1.509 38.33 0.083 2.11 *Communications wire is 22 AWG (0.35 mm 2 ), 7/30 (7 x 0.25 mm) stranding, bare copper with 0.016 (0.41 mm) thick insulation.

Previous Page
Next Page