Alpha Wire Industrial Series Tray Rated Cable Page 15 Series V and V-Flex VFD Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 15 Series V VFD Cable Enhanced Design for Superior Performance in Variable-Frequency Drives 600/1000 V Shielded, 3 Conductor Series V cables for variable-frequency drives (VFD) set the standard in high- performance and reliable connectivity. Their specially formulated cross-linked polyeth- ylene insulation provides superior corona resistance, low capacitance for longer runs, and excellent low-temperature properties. A symmetrical design places the ground wires in the interstices of the conductors for uniform conductor-to-ground capacitance and impedance. Smaller gauge cable feature a combination foil + braid shield to offer exceptional EMI/RFI protection in noisy environments. On larger gauge cable, a double copper tape is used to provide the same noise-free operation. This uniformity reduces the probability of motor damage from common-mode current. Alpha Series V VFD cables are compatible with drives from all major manufacturers. UL RHW-2 (16 - 2 AWG) UL XHHW-2 UL TC-ER UL 1000V Flexible Motor Supply Cable CSA AWM I/II A/B FT4 CE LVD 2006/95/EC Pennsylvania MSHA Operating Temperature -40C to +90C Conductor Color Coding Black, numbered Materials Stranded tinned copper conductors Stranded tinned copper ground wires Cross-linked polyethylene insulation (XLPE) Shielding 16 - 4 AWG: Aluminum/polyester/aluminum foil and tinned copper braid with 85% coverage 2 - 4/0 AWG: Double-layer copper tape Black premium PVC jacket Voltage 600 V (UL TC-ER) 1000 V (UL Motor Supply) Features UL Direct Burial UL Sunlight Resistant 10x bend radius Suitable for use in Class I, Division 2 locations per Article 501 of the National Electric Code Availability Bulk, made to order FIT Tubing Recommendations FIT-221: General-purpose cross-linked polyolefin FIT-321V: Low-shrink- temperature, flame-retardant cross-linked polyolefin Three-Conductor VFD Cables Part No. Wire Size Stranding Shielding Insulation Thickness Jacket Thickness Nominal Diameter AWG mm 2 AWG mm Inch mm Inch mm Inch mm V16316 16 1.32 26/30 26 x 0.25 Foil + Braid 0.046 1.17 0.050 1.27 0.468 11.89 V16314 14 2.09 41/30 41 x 0.25 Foil + Braid 0.046 1.17 0.065 1.65 0.538 13.67 V16312 12 3.31 65/30 65 x 0.25 Foil + Braid 0.046 1.17 0.065 1.65 0.578 14.68 V16310 10 5.37 105/30 105 x 0.25 Foil + Braid 0.047 1.19 0.065 1.65 0.642 16.31 V16308 8 8.53 133/29 133 x 0.28 Foil + Braid 0.061 1.55 0.065 1.65 0.798 20.27 V16306 6 13.57 133/27 133 x 0.36 Foil + Braid 0.061 1.55 0.085 2.15 0.924 23.47 V16304 4 21.58 133/25 133 x 0.45 Foil + Braid 0.061 1.55 0.085 2.15 1.050 26.67 V16302 2 34.32 133/23 133 x 0.57 Tape 0.061 1.55 0.085 2.15 1.157 29.39 V16001 1 43.28 133/22 133 x 0.64 Tape 0.056 1.42 0.085 2.15 1.197 30.48 V16000 1/0 54.58 133/21 133 x 0.72 Tape 0.056 1.42 0.085 2.15 1.294 32.77 V16020 2/0 68.85 133/20 133 x 0.81 Tape 0.056 1.42 0.085 2.15 1.399 35.56 V16030 3/0 86.9 133/19 133 x 0.91 Tape 0.056 1.42 0.085 2.15 1.517 38.53 V16040 4/0 109 133/18 133 x 1.02 Tape 0.056 1.42 0.085 2.15 1.653 41.98

Previous Page
Next Page