Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 24 20 AWG (0.616 mm 2 ) Stranding: 19/32 (19 x 0.203 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs Nominal Diameter Inch mm 78242 2 0.237 6.02 78253 3 0.253 6.43 78244 4 0.279 7.09 78245 5 0.308 7.82 78246 6 0.338 8.59 78248 8 0.369 9.37 78249 9 0.400 10.16 22 AWG (0.382 mm 2 ) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.007 (0.18 mm) Jacket thickness: 0.015 (0.38 mm) Part Number Pairs Nominal Diameter Inch mm 78232 2 0.209 5.31 78243 3 0.222 5.64 78234 4 0.245 6.22 78235 5 0.270 6.86 78236 6 0.296 7.52 78238 8 0.322 8.18 78239 9 0.349 8.86 UL AWM 21460 UL VW-1 CSA I A/B FT1 Temperature Range -40C to + 80C Conductor Color Coding Chart B (Chart A for 20 AWG) Materials Tinned copper conductors mPPE insulation Aluminum/polyester tape shield, 25% overlap, foil facing inward mPPE jacket, slate Properties Zero halogen Specific gravity: 1.03 100% recyclable Low outgassing Suitable for use in NFPA 79 applications Availability 100 ft (30.5 m) 1000 ft (305 m) Bulk, cut to length FIT Tubing Recommendations FIT-221L: Low smoke zero halogen FIT Spiral Wrap: Zero-halogen wrap simplifies wire harnessing, cabling, and bundling EcoCable Mini 300 V Overall Foil Shield and Individually Shielded Pairs, Multipair