Master Catalog Page 116 Xtra-Guard Flex Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 116 Cable > Xtra-Guard > Xtra-Guard Flex > Multiconductor > Foil/Spiral Shield > 300 V Xtra-Guard Continuous Flex Data C-Track or High Flexing Applications Up to 6 Million Flex Life Cycles 300 V Foil/Spiral Shield, Multiconductor UL CM UL AWM 2661 CSA AWM I/II A/B FT4 CSA CMG CE Operating Temperature +5C to 105C (flexing) -10C to 105C (stationary) Conductor Color Coding Chart D (page 531) Jacket color: slate Materials Finely stranded tinned copper conductors Lubricated semi-rigid PVC insulation Foil +spiral shield Aluminum/polyester foil shield, 25% overlap min. Foil facing outward Tinned copper spiral shield, 90% coverage Oil-resistant PVC jacket Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT Tubing Recommendations FIT-FLEX: Highly flexible, cross-linked silicone rubber FIT-650: Chemical/ temperature resistant cross- linked fluoroelastomer 28 AWG (0.09 mm 2 ) Stranding: 7/36 (7 x 0.13 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 86002CY 2 0.174 4.42 0.040 1.02 86003CY 3 0.180 4.57 0.040 1.02 86004CY 4 0.190 4.83 0.040 1.02 86005CY 5 0.200 5.08 0.040 1.02 86007CY 7 0.223 5.66 0.040 1.02 86012CY 12 0.283 7.19 0.040 1.02 86018CY 18 0.282 7.16 0.040 1.02 86025CY 25 0.329 8.36 0.040 1.02 26 AWG (0.14 mm 2 ) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 86102CY 2 0.182 4.62 0.040 1.02 86103CY 3 0.188 4.78 0.040 1.02 86104CY 4 0.199 5.05 0.040 1.02 86105CY 5 0.211 5.36 0.040 1.02 86107CY 7 0.237 6.02 0.040 1.02 86112CY 12 0.303 7.70 0.040 1.02 86118CY 18 0.302 7.67 0.040 1.02 86125CY 25 0.355 9.02 0.040 1.02 24 AWG (0.20 mm 2 ) Stranding: 10/34 (10 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 86202CY 2 0.192 4.88 0.040 1.02 86203CY 3 0.199 5.05 0.040 1.02 86204CY 4 0.211 5.36 0.040 1.02 86205CY 5 0.225 5.72 0.040 1.02 86207CY 7 0.253 6.43 0.040 1.02 86212CY 12 0.327 8.31 0.040 1.02 86218CY 18 0.327 8.31 0.040 1.02 86225CY 25 0.396 10.06 0.045 1.14 22 AWG (0.38 mm2) Stranding: 19/34 (19 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 86302CY 2 0.208 5.28 0.040 1.02 86303CY 3 0.217 5.51 0.040 1.02 86304CY 4 0.231 5.87 0.040 1.02 86305CY 5 0.247 6.27 0.040 1.02 86307CY 7 0.280 7.11 0.040 1.02 86312CY 12 0.367 9.32 0.040 1.02 86318CY 18 0.367 9.32 0.040 1.02 86325CY 25 0.446 11.33 0.045 1.14

Previous Page
Next Page