Master Catalog Page 318 Communication and Control Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 318 Cable > Communication, Control and Industrial > Multiconductor > Foil Shield > 300 V Communication and Control 300 V Foil Shield, Multiconductor, SR-PVC, PVC UL AWM 2464 VW-1 UL CM CSA CMG FT4 Operating Temperature -20C to +80C (AWM) -20C to +75C (CM) -20C to +60C (CMG) Conductor Color Coding Chart F (page 532) Materials Stranded tinned copper conductors Semirigid PVC insulation Aluminum/polyester foil shield, 25% overlap min. Foil facing outward Stranded tinned copper drain wire equal in size to conductor Slate PVC jacket Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) 24 AWG (0.22 mm 2 ) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 6300/3* 3 0.163 4.14 0.032 0.81 6300/4* 4 0.174 5.44 0.032 0.81 6305 5 0.187 4.75 0.032 0.81 6306* 6 0.201 5.11 0.032 0.81 6300/8* 8 0.214 5.44 0.032 0.81 6300/10* 10 0.244 6.20 0.032 0.81 6307 15 0.270 6.86 0.032 0.81 6308 20 0.298 7.57 0.032 0.81 6309 25 0.332 8.43 0.032 0.81 6310 30 0.366 9.30 0.040 1.02 6311 40 0.406 10.31 0.040 1.02 6312 50 0.453 11.51 0.045 1.14 Mutual capacitance: 32 pF/ft (105 pF/m) Ground capacitance: 58 pF/ft (190 pF/m) *Color coding: 1 Black, 2 White, 3 Red, 4 Green, 5 Brown, 6 Blue, 7 Orange, 8 Yellow, 9 Violet, 10 Slate.