Master Catalog Page 61 Xtra-Guard 2 Oil-and Abrasion-Resistant Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 61 Cable > Xtra-Guard > Xtra-Guard 2 > Multiconductor > Foil Shielded > 300 V Xtra-Guard 2 Oil and Abrasion Resistant 300 V Foil Shielded, Multiconductor UL AWM 20668 VW-1 CSA AWM I/II A/B FT1 Operating Temperature -30C to +90C Conductor Color Coding 24, 22 AWG: Chart E (page 532) 20, 18, 16 AWG: Chart D (page 531) Nine jacket colors (black standard) Custom colors available Materials Stranded tinned copper conductors Premium PVC insulation Specially formulated polyurethane jacket UV resistant Aluminum/polyester/aluminum foil shield, with 25% overlap and foil facing inward Tinned copper drain wire sized the same as cable conductors Nylon ripcord Availability Made to order 1000 ft (305 m) minimum FIT Tubing Recommendations FIT-750: Bonding adhesive lined, cross-linked polyolefin 24 AWG (0.23 mm 2 ) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25092 2 0.160 4.06 0.032 0.81 25093 3 0.167 4.24 0.032 0.81 25094 4 0.179 4.55 0.032 0.81 25096 6 0.205 5.21 0.032 0.81 25098 8 0.219 5.56 0.032 0.81 25100 10 0.248 6.30 0.032 0.81 25100/15 15 0.275 6.99 0.032 0.81 25100/20 20 0.304 7.72 0.032 0.81 25100/25 25 0.336 8.53 0.032 0.81 22 AWG (0.35 mm 2 ) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25192 2 0.172 4.37 0.032 0.81 25193 3 0.180 4.57 0.032 0.81 25194 4 0.193 4.90 0.032 0.81 25196 6 0.223 5.66 0.032 0.81 25198 8 0.239 6.07 0.032 0.81 25199/10 10 0.272 6.91 0.032 0.81 25199/15 15 0.303 7.70 0.032 0.81 25199/20 20 0.335 8.51 0.032 0.81 25199/25 25 0.372 9.45 0.032 0.81 25199/30 30 0.393 9.98 0.032 0.81 25199/40 40 0.438 11.13 0.032 0.81 25199/50 50 0.482 12.24 0.032 0.81 20 AWG (0.56 mm 2 ) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25462 2 0.212 5.38 0.032 0.81 25463 3 0.223 5.66 0.032 0.81 25464 4 0.242 6.15 0.032 0.81 25466 6 0.284 7.21 0.032 0.81 25468 8 0.306 7.77 0.032 0.81 25470 10 0.352 8.94 0.032 0.81 25470/15 15 0.395 10.03 0.032 0.81 25470/20 20 0.441 11.20 0.032 0.81 25470/25 25 0.492 12.50 0.032 0.81 25470/30 30 0.521 13.23 0.032 0.81 25470/40 40 0.626 15.90 0.053 1.35 25470/50 50 0.688 17.48 0.053 1.35

Previous Page
Next Page