Master Catalog Page 64 Xtra-Guard 2 Oil-and Abrasion-Resistant Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 64 Cable > Xtra-Guard > Xtra-Guard 2 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard 2 Oil and Abrasion Resistant 300 V Supra-Shield Foil/Braid, Multiconductor UL AWM 20668 VW-1 CSA AWM I/II A/B FT1 Operating Temperature -30C to +90C Conductor Color Coding 24, 22 AWG: Chart E (page 532) 20, 18, 16 AWG: Chart D (page 531) Nine jacket colors (black standard) Custom colors available Materials Stranded tinned copper conductors Premium PVC insulation Specially formulated polyurethane jacket UV resistant Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. Nylon ripcord Availability Made to order 1000 ft (305 m) minimum FIT Tubing Recommendations FIT-750: Bonding adhesive lined, cross-linked polyolefin 24 AWG (0.23 mm 2 ) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25112 2 0.184 4.67 0.032 0.81 25113 3 0.191 4.85 0.032 0.81 25114 4 0.203 5.16 0.032 0.81 25116 6 0.229 5.82 0.032 0.81 25118 8 0.243 6.17 0.032 0.81 25120 10 0.272 6.91 0.032 0.81 25120/15 15 0.299 7.59 0.032 0.81 25120/20 20 0.328 8.33 0.032 0.81 25120/25 25 0.360 9.14 0.032 0.81 25120/30 30 0.378 9.60 0.032 0.81 25120/40 40 0.418 10.62 0.032 0.81 25120/50 50 0.457 11.61 0.032 0.81 22 AWG (0.35 mm 2 ) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25102 2 0.196 4.97 0.032 0.81 25103 3 0.204 5.18 0.032 0.81 25104 4 0.217 5.51 0.032 0.81 25106 6 0.247 6.27 0.032 0.81 25108 8 0.263 6.68 0.032 0.81 25110 10 0.296 7.52 0.032 0.81 25110/15 15 0.327 8.31 0.032 0.81 25110/20 20 0.359 9.12 0.032 0.81 25110/25 25 0.396 10.06 0.032 0.81 25110/30 30 0.417 10.59 0.032 0.81 25110/40 40 0.462 11.73 0.032 0.81 25110/50 50 0.506 12.85 0.032 0.81 20 AWG (0.56 mm 2 ) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 25152 2 0.236 5.99 0.032 0.81 25153 3 0.247 6.27 0.032 0.81 25154 4 0.266 6.76 0.032 0.81 25156 6 0.308 7.82 0.032 0.81 25158 8 0.330 8.38 0.032 0.81 25160 10 0.376 9.55 0.032 0.81 25160/15 15 0.419 10.64 0.032 0.81 25160/20 20 0.465 11.81 0.032 0.81 25160/25 25 0.516 13.11 0.032 0.81 25160/30 30 0.545 13.84 0.032 0.81 25160/40 40 0.656 16.66 0.053 1.35 25160/50 50 0.718 18.24 0.053 1.35

Previous Page
Next Page