Master Catalog Page 86 Xtra-Guard 4 Advanced Temperature and Chemical Performance Cable

Alpha Wire www.alphawire.com 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 86 Cable > Xtra-Guard > Xtra-Guard 4 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard 4 Advanced Temperature and Chemical Performance 300 V Supra-Shield Foil/Braid, Multiconductor UL AWM 20237 UL PLTC CSA AWM I/II A/B FT1 MSHA P-07-KA070017-MSHA NEC Class 1, Div 2 (22 & 20 AWG) Operating Temperature -50C to +125C Conductor Color Coding 24, 22 AWG: Chart E (page 532) 20, 18, 16 AWG: Chart D (page 531) Nine jacket colors (black standard) Custom colors available Materials Stranded tinned copper conductors TPE insulation TPE jacket Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. Nylon ripcord Availability Made to order 1000 ft (305 m) minimum FIT Tubing Recommendations FIT-600: highly flexible, cross-linked elastomer FIT-400: temperature/chemical resistant FEP 24 AWG (0.23 mm 2 ) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 45112 2 0.228 5.79 0.042 1.07 45113 3 0.237 6.02 0.042 1.07 45114 4 0.252 6.40 0.042 1.07 45116 6 0.285 7.24 0.042 1.07 45118 8 0.303 7.70 0.042 1.07 45120 10 0.340 8.64 0.042 1.07 45120/15 15 0.375 9.53 0.042 1.07 45120/20 20 0.411 10.44 0.042 1.07 45120/25 25 0.452 11.48 0.042 1.07 22 AWG (0.35 mm 2 ) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 45102 2 0.246 6.25 0.045 1.14 45103 3 0.256 6.50 0.045 1.14 45104 4 0.272 6.91 0.045 1.14 45106 6 0.309 7.85 0.045 1.14 45108 8 0.329 8.36 0.045 1.14 45110 10 0.370 9.40 0.045 1.14 45110/15 15 0.428 10.87 0.055 1.40 45110/20 20 0.469 11.91 0.055 1.40 45110/25 25 0.514 13.06 0.055 1.40 20 AWG (0.56 mm 2 ) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Conductors Nominal Diameter Jacket Thickness Inch mm Inch mm 45152 2 0.262 6.65 0.045 1.14 45153 3 0.273 6.93 0.045 1.14 45154 4 0.292 7.42 0.045 1.14 45156 6 0.334 8.48 0.045 1.14 45158 8 .0356 9.04 0.045 1.14 45160 10 0.422 10.72 0.055 1.40 45160/15 15 0.465 11.81 0.055 1.40 45160/20 20 0.511 12.98 0.055 1.40 45160/25 25 0.562 14.27 0.055 1.40 * UL AWM 20237, CSA AWM I/II A/B FT1 only

Previous Page
Next Page